Remedi Portable Dental X-Ray Device

In stock
SKU: REM.1559
Regular price 1,184,900.00 AMD inc. VAT
You can contact us for your orders and questions. +90543 456 2614
All your orders are sent by fast air cargo with UPS EXPRESS Shipping
Your orders will be prepared and shipped within 3 business days.

REMEX-T (K) 100 Portable X-Ray Equipment

The REMEX-T (K) 100 Portable X-ray Equipment is designed for use by trained dentists and dental technicians as an extra-oral x-ray source to produce diagnostic x-ray images using intra-oral imaging. It is intended for use on adults, children, and pregnant women.

Responsibilities and Compliance:

  • The owner/operator is responsible for verifying ongoing compliance with exposure limits, leakage radiation, beam alignment, and calibration of kVp and mA.
  • Annual verification may be required by a qualified service technician, as mandated by federal law.
  • Compliance with local, state, and federal regulations is the responsibility of the owner/operator.

Cleaning Instructions:

  • Ensure the adapter is unplugged before cleaning.
  • Ensure the power is off on the REMEX-T (K) 100 during cleaning.
  • Use only an alcohol-based disinfectant with a tissue or cloth moistened with liquid or spray.
  • The REMEX-T (K) 100 and its adapter must not be subjected to any sterilization procedure.

Specifications:

  • Classification: Class IIb (Annex IX, Rule 10, Council Directive 93/42/EEC as amended by Directive 2007/47/EC)
  • Model: REMEX-T100, REMEX-K100 (model name varies by X-ray tube)
  • Electric Shock Protection Type:
    • Class II equipment (Exposure mode)
    • Built-in power supply equipment (Charge mode)
    • Type B Applied part

Power Specifications:

  • AC/DC Adapter:
    • Input: 100-240 Vac, 50/60 Hz, 1.5 A
    • Output: 12.6 Vdc, 1.5 A
  • Rechargeable Battery:
    • 11.1 Vdc, 1500 mAh
  • Power Input: 160 VA (in charging mode)

X-Ray Tube Specifications:

  • Tube Voltage: 70 kV (Fixed)
  • Tube Current: 2 mA (Constant)
  • Exposure Time Range: 0.01 s ~ 1.3 s
  • Focal Spot Size: 0.4 mm (conforming to IEC 60336: 1993)
  • Natural Filtration: Min. 1.0 mmAl / 0.8 mmAl

Filament Characteristics:

  • 1.0 ~ 4.0 V, 2.2 ~ 3.0 A (max filament current)
  • 2.0 ~ 3.5 V, 2.2 ~ 3.0 A (max filament current)

Anode Specifications:

  • Angle: 12.5°/12.0°
  • Thermal Properties: 4.3 kJ / 7.0 kJ
  • Maximum Anode Heat Dissipation Rate: 430 W / 560 W

Protection and Operation:

  • Water and Particulate Ingress Protection: IPX0
  • Mode of Operation: Continuous
    • Recharge time of the high voltage tank is 10 sec.
  • Expected Service Life: 5 years

Basic Performance:

  • Accuracy of Loading Factors:
    • Tube voltage accuracy: less than 10%
    • Tube current accuracy: less than 20%
    • Irradiation time accuracy: less than 5% + 50 ms
    • Tube current time accuracy: ± (10% +0.2 mAs)
  • Repeatability of Radiation Output:
    • Coefficient of variation of measured air kerma values: less than 0.05